10Ton to 20Ton Portable Air Cooled Chillers

From Whaley Products, Incorporated
(Click to see category)

SAP Series
1.5Ton – 5Ton
Single Circuit
208-230/1
SAP Series
3Ton – 10Ton
Single Circuit
208-230/3 – 460/3
SAP Series
12.5Ton – 20Ton
Single Circuit
208-230/3 – 460/3
SAP-D Series
10Ton – 20Ton
Dual Circuit
208-230/3 – 460/3

For Higher Capacity, Click Here
 

Whaley dual circuit chillers provide 2 individual circuits for optimum redundancy. Never have a downed process from chilled water system maintenance. If you ever have to work on one circuit of the SAP-D Series dual circuit chiller, there will always be another circuit up and running providing cooling to your application. WPI also offers dual circuit modular chillers as well. These are ideal for people who already have a pump and reservoir, or if you are wanting even more redundancy. Contact an experienced dual circuit cooling engineer today.

208-230/460/3 Dual Circuit 10 Ton – 20 Ton
Unit Specifications

Model #
Tonnage
KW
BTU/hr
Pumps
Volt
GPM
FLA
1Circ/
2Circ
SuppPump HP
Circ Pump HP
Tank
size
SAP10D-3-PT
10 Ton
35.1
120,000
Single
208-230/3
24
27.9 / 44.3
2hp #126
40 gal
SAP10D-3-2PT
10 Ton
35.1
120,000
Dual
208-230/3
24
30.1 / 46.5
2hp #126
0.5hp #69
40 gal
SAP10D-4-PT
10 Ton
35.1
120,000
Single
460/3
24
12.5 / 21.6
2hp #126
40 gal
SAP10D-4-2PT
10 Ton
35.1
120,000
Dual
460/3
24
13.5 / 22.6
2hp, #126
0.5hp #69
40 gal
SAP12.5D-3-PT
12.5 Ton
43.9
150,000
Single
208-230/3
30
29.5 / 51.5
2hp #126
40 gal
SAP12.5D-3-2PT
12.5 Ton
43.9
150,000
Dual
208-230/3
30
33.5 / 55.5
2hp #126
1hp #11
40 gal
SAP12.5D-4-PT
12.5 Ton
43.9
150,000
Single
460/3
30
14.6 / 25.8
2hp #126
40 gal
SAP12.5D-4-2PT
12.5 Ton
43.9
150,000
Dual
460/3
30
18.6 / 29.8
2hp #126
1hp #11
40 gal
SAP15D-3-PT
15 Ton
52.7
180,000
Single
208-230/3
36
38.1 / 69.3
3hp #16
60 gal
SAP15D-3-2PT
15 Ton
52.7
180,000
Dual
208-230/3
36
42.1 / 73.3
3hp #16
1hp #11
60 gal
SAP15D-4-PT
15 Ton
52.7
180,000
Single
460/3
36
18.3 / 34.4
3hp #16
60 gal
SAP15D-4-2PT
15 Ton
52.7
180,000
Dual
460/3
36
20.1 / 36.2
3hp #16
1hp #11
60 gal
SAP20D-3-PT
20 Ton
70.3
240,000
Single
208-230/3
48
43.2 / 80.5
3hp #16
60 gal
SAP20D-3-2PT
20 Ton
70.3
240,000
Dual
208-230/3
48
47.2 / 84.5
3hp #16
1hp #11
60 gal
SAP20D-4-PT
20 Ton
70.3
240,000
Single
460/3
48
22.8 / 43.4
3hp #16
60 gal
SAP20D-4-2PT
20 Ton
70.3
240,000
Dual
460/3
48
24.6 / 45.2
3hp #16
1hp #11
60 gal

 

Physical Specifications

 

Model #
Tonnage
KW
Voltage
Length
Width
Height
# of
Compressors
Inlet/outlet
Conections
SAP10D-3-PT
10 Ton
35.1
208-230/3
78″
44″
84″
2
1ea 1.25″
SAP10D-3-2PT
10 Ton
35.1
208-230/3
78″
44″
84″
2
1ea 1.25″
SAP10D-4-PT
10 Ton
35.1
460/3
78″
44″
84″
2
1ea 1.25″
SAP10D-4-2PT
10 Ton
35.1
460/3
78″
44″
84″
2
1ea 1.25″
SAP12.5D-3-PT
12.5 Ton
43.9
208-230/3
78″
44″
84″
2
1ea 1.25″
SAP12.5D-3-2PT
12.5 Ton
43.9
208-230/3
78″
44″
84″
2
1ea 1.25″
SAP12.5D-4-PT
12.5 Ton
43.9
460/3
78″
44″
84″
2
1ea 1.25″
SAP12.5D-4-2PT
12.5 Ton
43.9
460/3
78″
44″
84″
2
1ea 1.25″
SAP15D-3-PT
15 Ton
52.7
208-230/3
89″
68″
84″
2
1ea 1.5″
SAP15D-3-2PT
15 Ton
52.7
208-230/3
89″
68″
84″
2
1ea 1.5″
SAP15D-4-PT
15 Ton
52.7
460/3
89″
68″
84″
2
1ea 1.5″
SAP15D-4-2PT
15 Ton
52.7
460/3
89″
68″
84″
2
1ea 1.5″
SAP20D-3-PT
20 Ton
70.3
208-230/3
89″
68″
84″
2
1ea 1.5″
SAP20D-3-2PT
20 Ton
70.3
208-230/3
89″
68″
84″
2
1ea 1.5″
SAP20D-4-PT
20 Ton
70.3
460/3
89″
68″
84″
2
1ea 1.5″
SAP20D-4-2PT
20 Ton
70.3
460/3
89″
68″
84″
2
1ea 1.5″

 

Standard Features:

1. Condenser Fan2. Copper Tube / Enhanced Fin Coil3. High Efficiency Copeland Scroll Compressor4. heavy Gauge Steel Cabinet5. Refrigerant Line Connections, Electrical Inlets, & Service Valves

Condensing Unit Certifications & Accreditations
A proven condenser up to 14 SEER efficiency.

Direct drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity.

Vertical air discharge minimizes operating sounds.

TEFC motor for maximum protection from weather, dust, and corrosion.

Rain Shield on motor provides additional protection from moisture.

Ripple-edged aluminum condenser fins. Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer.

Fin collars grip tubing for maximum contact area.

Copper tube construction.

Coil is factory tested under high pressure to ensure leakproof construction.

Entire coil is accessible for simplified cleaning.

Compressor crank case heater for low ambient installations.

 

Copeland Scroll Compressors
Copeland compressors are utilized to provide the most efficient chiller system possible. Compa-Chill chillers credit the R-410a compressors for their reduced energy consumption, low vibration, reduced moving parts, and high resistance to liquid refrigerant return. 5 year compressor warranty is standard.

Supply Pumps
100’ TDH is standard design. Base mounted on sturdy 14 gauge steel to eliminate vibration, centrifugal iron TEFC motors are standard. For dual pump option, a smaller 40-60’ TDH recirculation pump is added to ensure proper water flow through evaporator to eliminate evaporator freeze-up. Many customers prefer this option for added security in the field.

Brazed SS Plate Heat Exchangers
A Stainless Steel 316SS is utilized to allow maximum heat exchange between refrigerant and water.

Insulated Reservoirs
Packaged units come standard with internal insulated rotomolded polypropylene reservoir for cold water storage. With dual pump option, reservoir is typically upgraded to a larger volume. to accommodate the extra flow in & out.

TXV’s, Filter Dryer, Sight Glass
Standard thermastatic expansion valves incorporate balanced port construction, which makes them ideally suited for applications with a wide range of operating conditions. Specially designed for the higher pressure associated with the high efficiency R-410a. Filter dryers and sight glasses installed in liquid line for added security and simplified maintenance.

Some Benefits of a Whaley Chiller

Energy Efficiency

R-410a is more efficient than earlier R-22 systems because the higher pressures of R-410a systems make for greater refrigerant mass flow rates through the TXV. Laboratory analysis and testing have shown that R410A allows higher heat transfer than R22, resulting in more efficient operation. So choosing a Whaley Chiller with R410A not only makes sense environmentally – it also makes sense from an economic standpoint.

Simplified Controls Equals Simplified Price

Digital Temperature Controls are utilized with easy to operate set point and temperature differential operation. The controller provides accurate temperature indication and control. Temperature is sensed from water outlet of evaporator. Available in Fahrenheit or Celsius measurement. Microprocessor control system available as option.

Chiller System Safeties

Adjustable low pressure switch, fixed high pressure switch, and head pressure fan cycling switch will all be utilized in WPI’s chiller systems ensuring the safety of system components at all times.

Evaporator Security

Dedicating a chiller circulation pump in addition to the supply pump ensures proper flow through the evaporator at all times. This eliminates the risk of freezing up an evaporator and damaging other key components in your system.

Warranty

Whaley Products offers 1 year warranty on parts and a 5 year compressor replacement warranty. This extended warranty for the compressor ensures you are getting the most of your investment with WPI.

24/7 Technical Support

Our technical support agents are available 24/7 to assist you in emergency cooling situations.